nanaxspirit.blogg.se

Protel 99se footprint library
Protel 99se footprint library





  1. Protel 99se footprint library install#
  2. Protel 99se footprint library 64 Bit#
  3. Protel 99se footprint library Pc#
  4. Protel 99se footprint library windows#

I rewrote the INI file to point to the "Transistors.ddb" as in ThisIsNewID's example just above.

Protel 99se footprint library install#

The next thing I tried was to install the default Protel libraries to see if there was something wrong with my file. If you have done that, move your LIB file to the root directory of the DDB, delete the Documents folder and empty the Recycle Bin of that DDB. When you create a DDB, the default is that it creates a "Documents" folder and I have always put my files in that folder.ĭon't do that. I always use my own footprints as I hate the ones that Protel supplies.

Protel 99se footprint library 64 Bit#

I am using Win 7 Professional 64 Bit with Protel 99 SE SP6. It took a while and I finally got it to work, but it may be different for every machine. OK, I spent a lot of time on this one and also contacted people on the PEDA (Protel EDA) Forum, dedicated to Protel 99SE users. Below is my changes to include the Transistors.ddb(Transistors.lib).įile0=D>MSACCESS:$RP>C:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Advpcb.ddb$OP>$ON>PCB Footprints.lib$ID>-1$ATTR>0$E>PCBLIB$STF>įile1=D>MSACCESS:$RP>C:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Transistors.ddb$OP>$ON>Transistors.lib$ID>-1$ATTR>0$E>PCBLIB$STF>įile0=D>MSACCESS:$RP>C:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Transistors.ddb$OP>$ON>Transistors.lib$ID>-1$ATTR>0$E>PCBLIB$STF>įile1=D>MSACCESS:$RP>C:\Program Files\Design Explorer 99 SE\Library\Pcb\Generic Footprints$RN>Advpcb.ddb$OP>$ON>PCB Footprints.lib$ID>-1$ATTR>0$E>PCBLIB$STF> There are two locations to change and those are and sections. First need to find out the name of the ddb and llb names that you are interested than close the program and edit the ini file. I'd be interested to know if you get this one solved, becasue we're all going to have to move to Win 7 or some derivative some time and need be able able to access our old files from old versions of CAD SW (to the *nix fanboys: no, Protel/Altium is not supported on Linux/Mac etc so that's not a choice we can make).ĭave's solution work for me.

Protel 99se footprint library Pc#

Virtual PC aka "XP Mode" works (all this from fairly quick tests obviously) but is vastly slower than native so might as well stick with a 5 year old PC if you want to use Protel 99SE. Virtualbox has nasty redraw delays making it unusable for anything with polygons (fast until it reaches a certain track limit then it freezes repeatedly during redraws). Screen redraw faster than native I think (another Win 7 problem?).

Protel 99se footprint library windows#

Sorry I can't help, other than to say the lastest version of VMware Player worked quite well with Protel in Windows 2000 / etc except for a small annoying mouse click delay. That's an eye opener - had I known that I would have made the decision to downgrade Win 7 much earlier and saved myself a lot of time! Protel was one of the first apps I checked as it's a "must work" for my job, I obviously didn't go deep enough. Make a new DDB - locks up and can't go any further. Of course it loses all my settings (or rather recreates them from scratch as above). (Another reason to downgrade Win 7 to XP.) Damn, same error you get when loading libraries, can't go any further. Interested so trying it now on my new (but useless) 8 core machine - I'm an administrator, but UAC enabled. A nice idea, but Windows' implementation is a little flawed - if you then execute the app "as administrator" to solve some compatibility issue, then it forgets about the files in the virtual store and recreates them in \windows or wherever. I installed it with UAC enabled, which redirects all the silly files Protel puts in the windows directory to the virtual store. Yes, I am administrator, I can't remember if it asked for admin priveledges when installing, I don't think so.